RSL-100: Rockwell Software RSLinx Software
|
| |
| Course Description |
| This 8-hour (1-day) course allows students to gain hands on experience using Rockwell software RSLinx software to configure, understanding, and troubleshooting PLC communications for Allen-Bradley SLC-500, MicroLogix and PLC-5 systems. |
| |
| Topical Outline |
- Introduction to RSLinx
- Communication protocols used by processors - RS232, DH+, DH485, Ethernet
- Configuring RSLinx Drivers - RS232, DH+, DH485, Ethernet
- Configuring address and channel communication for Allen-Bradley Processors
- Selecting proper cable for driver type
- Troubleshooting various communication problems
- Hands-on setting up RSLinx drivers and communication with a processor at various stations setup in classroom
|
| |
| Prerequisites |
| Students should be familiar with Allen Bradley programmable controllers, and Windows 2000 or Windows XP. Basic knowledge of RSLogix5 or RSLogix500 software for the particular programmable controller is desirable.THIS IS NOT AN ENTRY LEVEL TRAINING PROGRAM |
| |
| Course Length |
| 8 hours / 1 day |
| |
| CEU's |
| .7 |
| |
| Objectives |
| Persons successfully completing this course will be able to:
|
| |
| Click here to download this course description in a printable PDF. |
|
|
A-760: Rockwell FactoryTalk View ME HMI Software Maintenance & Troubleshooting
|
| |
| Course Description |
| This 36 hour training program is designed for the maintenance troubleshooter to enable them to use PanelView Plus terminals, FactoryTalk View ME and FactoryTalk View Studio to assist in correcting line stoppages and errors. Emphasis is on troubleshooting rather that on programming, although exposure to the many software features is included. It is assumed that the technician will be using existing FactoryTalk View ME, Communications, and PLC programs. |
| |
| Topical Outline |
-
Saving and Restoring Projects
-
Adding and Revising Tags in the Database
-
Configuring Communication
-
Adding Objects to Graphic displays
-
Attaching Controls to Graphic displays
-
Configuring Animation on Graphic Objects
-
Configuring Events
-
Configuring Alarms
-
Configuring Logging
-
Creating Macros
-
Configuring Trends
-
Configuring Project Security
-
Running an FactoryTalk View ME Project
|
| |
| Prerequisites |
Students should have a thorough knowledge of the following:
-
Basic Windows Skills
-
Level One PLC (for specific PLC they will be using with FactoryTalk View32)
-
One of the PanelView families and the corresponding Panel Builder software
-
RSLinx Configuration and Troubleshooting
|
| |
| Course Length |
| 36 hours / 4.5 days |
| |
| CEU's |
| 3.3 |
| |
| Objectives |
Persons successfully completing this course will be able to:
-
Open FactoryTalk View Studio and select the correct project for the troubleshooting task at hand.
-
Trace communications between FactoryTalk View ME objects and tags to and from PLC programs.
-
Use RSLinx Enterprise and OPC communications drivers to troubleshoot communications problems.
-
Use the Tag Database to add and make minor edits to memory and device tags.
-
Open the Graphic Display Editor and identify tags associated with objects.
-
Use the Graphic Display Editor to add and make minor edits to objects.
-
Open, evaluate, and make minor edits to Expressions used in object dialog boxes.
-
Track and make minor edits to display Navigation commands.
-
Use the Alarm Monitor to view and acknowledge alarms.
-
Use the Alarm Editor to add and make minor edits to alarms.
-
Setup and edit data Trends.
|
| |
| Click here to download this course description in a printable PDF. |
|
|
A-770: Rockwell FactoryTalk View SE HMI Software Maintenance & Troubleshooting
|
| |
| Course Description |
| This 36-hour course is designed for the maintenance troubleshooter to enable him or her to use FactoryTalk View Studio programs and FactoryTalk View Client to assist in correcting line stoppages and errors. Emphasis is on troubleshooting rather than programming. It is assumed the technician will be using existing FactoryTalk View SE projects, Communications and PLC programs. |
| |
| Topical Outline |
- Saving and Restoring Projects
-
Adding and Revising Tags in the Database
-
Configuring Communication
-
Adding Objects to Graphic displays
-
Attaching Controls to Graphic displays
-
Configuring Animation on Graphic Objects
-
Configuring Events
-
Configuring Alarms
-
Configuring Activity Logs
-
Configuring Data Logging Files
-
Creating Macros and Symbols
-
Configuring Trends
-
Configuring Project Security
- Running an FactoryTalk View Project
|
| |
| Prequisites |
Students should have a thorough knowledge of the following:
-
Basic Windows Skills
-
Level One PLC (for specific PLC they will be using with FactoryTalk View32)
-
One of the PanelView families and the corresponding Panel Builder software
-
RSLinx Configuration and Troubleshooting
|
| |
| Course Length |
| 36 hours / 4.5 days |
| |
| CEU's |
| 3.3 |
| |
| Objectives |
|
Persons successfully completing this course will be able to:
-
Open FactoryTalk View Studio and select the correct project for the troubleshooting task at hand.
-
Trace communications between FactoryTalk View SE objects and tags to and from PLC programs.
-
Use RSLinx Enterprise and OPC communications drivers to troubleshoot communications problems.
-
Use the Tag Database to add and make minor edits to memory and device tags.
-
Open the Graphic Display Editor and identify tags associated with objects.
-
Use the Graphic Display Editor to add and make minor edits to objects.
-
Open, evaluate, and make minor edits to Expressions used in object dialog boxes.
-
Track and make minor edits to display Navigation commands.
-
Use the Alarm Monitor to view and acknowledge alarms.
-
Use the Alarm Editor to add and make minor edits to alarms.
-
Evaluate the effect of Event commands and make minor edits to Events.
-
Setup and edit data Trends.
-
Use System Tags to help correct problems.
|
| |
| Click here to download this course description in a printable PDF. |